Z-WALL ALLOWABLE LOAD TABLE No.11

Verticals = C 3 x 4.1       Diagonals = 2" x 2"x 12 Ga.

LOCATION: At Garage below 4x12 or 4x14
Plate Ht. Width & Height Designation Earthquake
Maximum Shear(lbs)
Wind  
Maximum Shear (lbs)
Drift2 
(inches)
  P=0k P=2k P=4k P=0k P=2k P=4k  
8'1" 17.5" x 82.25" Z 17.5 x 82.25 6300 5800 5300 4500 4140 3790 .284
  23.5" X 82.25" Z 23.5 X 82.25 8700 7940 7240 6210 5670 5170 .270
 
9'1" 17.5" X 94.25" Z 17.5 X 94.25 5450 5050 4600 3960 3610 3280 Use 97"
  23.5" X 94.25" Z 23.5 X 94.25 7350 6750 6130 5250 4820 4380 Use 97"
LOCATION: Below 4x6 or 4x8 header
Plate Ht Width & Height Designation Seismic
Maximum Shear(lbs)
Wind
Maximum Shear (lbs)
Drift2
(inches)
  P=0k P=2k P=4k P=0k P=2k P=4k  
8'1 17.5" X 85" Z 17.5 X 85 6000 5500 5060 4290 3930 3610  
 
9'1" 17.5" X 97" Z 17.5 X 97 5450 5050 4600 3960 3610 3280 .361
  23.5" X 97" Z 23.5 X 97 7350 6750 6130 5250 4820 4380 .321
  29.5"X 97" Z 29.5X 97 7750 7750 7750 5530 5530 5530 .267
 
10'1' 23.5" X 109" Z 23.5 X 109 6150 5600 5100 4390 4000 3640 Use 116.25"
  29.5" X 109" Z 29.5 X 109 6290 6250 5820 4490 4460 4160 Use 116.25"
LOCATION: Below double top plates
Plate Ht Width & Height Designation Seismic
Maximum Shear(lbs)
Wind
Maximum Shear (lbs)
Drift2
  P=0k P=2k P=4k P=0k P=2k P=4k  
8'1" 17.5"X 92.25" Z 17.5X 92.25 5780 5300 4820 4130 3780 3440 .303
  23.5" X 92.25" Z 23.5 X 92.25 7700 7060 6450 5500 5043 4607 .285
  29.5" X 92.25" Z 29.5 X 92.25 8000 7500 7000 5714 5357 5000 .243
 
9'1" 17.5" X 104.25" Z 17.5 X 104.25 4700 4250 3750 3360 3030 2680 .370
  23.5"X 104.25" Z 23.5 X 104.25 6850 6250 5700 4890 4460 4070 .354
  29.5" X 104.25" Z 29.5 X 104.25 7020 7020 7020 5010 5010 5010 .279
 
10'1' 17.5" X 116.25" Z 17.5 X 116.25 4000 3500 3100 2860 2500 2210 .447
  23.5"X 116.25" Z 23.5 X 116.25 6150 5600 5100 4390 4000 3640 .412
  29.5"X116.25" Z 29.5"X116.25" 6290 6250 5820 4490 4630 4160 .314
 

1The Allowable Vertical(Dead + Live) Loads are indicated by P=0 k, P=2 k, P=4 k. This Load is assumed to be acting simultaneously
  on both columns of the frame, in addition to the Seismic (Earthquake) or Wind Load. All of the appropriate 1997 UBC Load
  Combinations have been included,therefore enter this table with E, not with E/1.4.

2 Drift is calculated using Risa 2D, and Allowable Stress Design(D+L+E/1.4) and (D+L+W).